Download
|
Duct |
Promatect L500 ≥ 30 mm |
Gap between duct and damper (≤ 6 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 60 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Geoflam ≥ 30 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 60 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Geotec ≥ 30 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 60 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Tecniver ≥ 35 mm |
Gap between duct and damper (≤ 6 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 60 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Glasroc F V500 ≥ 35 mm |
Gap between duct and damper (≤ 6 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 60 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Exthamat ≥ 25 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 60 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Desenfire HD ≥ 25 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 60 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Promatect L500 ≥ 40 mm |
Gap between duct and damper (≤ 6 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 90 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Geoflam ≥ 35 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 90 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Tecniver ≥ 45 mm |
Gap between duct and damper (≤ 6 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 90 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Exthamat ≥ 30 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 90 (ved hod i o) S 1500 AA multi |
|
|
Duct |
Desenfire THD ≥ 25 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 90 (ved hod i o) S 1500 AA multi |
|
Download
|
Shaft |
Reinforced concrete (≥ 2150 kg/m³) ≥ 70 mm |
Mortar |
EI 90 (ved i o) S 1500 AA multi |
|
Download
|
Duct |
Promatect L500 ≥ 50 mm |
Gap between duct and damper (≤ 6 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 120 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Geoflam ≥ 45 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 120 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Geoflam Light ≥ 35 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 120 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Geotec ≥ 45 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 120 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Tecniver ≥ 50 mm |
Gap between duct and damper (≤ 6 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 120 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Glasroc F V500 ≥ 50 mm |
Gap between duct and damper (≤ 6 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 120 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Exthamat ≥ 35 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 120 (ved hod i o) S 1500 AA multi |
|
Download
|
Duct |
Desenfire HD ≥ 35 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 120 (ved hod i o) S 1500 AA multi |
|
|
Duct |
Desenfire STR ≥ 25 mm |
Gap between duct and damper (≤ 80 mm) sealed with refractory kit (on a depth ≥ 105 mm) |
EI 120 (ved hod i o) S 1500 AA multi |
|
Download
|
Shaft |
Masonry, concrete blocks, concrete ≥ 100 mm |
Mortar |
EI 120 (ved i o) S 1500 AA multi |